HPE Proliant DL380P G8

End of life Date:
June 30, 2021
OEM:
HPE
Type:
Server Computer

HPE ProLiant DL380p Gen8 Server - Specifications:-

Physical specifications

Specification Description

Dimensions (H x W x D)(with bezel) "SFF Drives: 8.73 x 44.55 x 69.85 cm (3.44 x 17.54 x 27.50 in)

LFF Drives: 8.73 x 44.55 x 74.93 cm (3.44 x 17.54 x 29.50 in)"

Weight (approximate) "Maximum(all hard drives, power supply, and processor installed): 27.66 kg (61.00 lb)

Minimum (one hard drive, power supply, and processor installed): 18.59 kg (41.0 Electrical specifications

Specification Description

Rated line voltage "100 to 120 V ac

200 to 240 V ac"

Rated input current "For 1200-W power supply:
10 A (at 100 V ac)

4.9 A (at 200 V ac)

For 750-W power supply:
8.9 A (at 100 V ac)

4.3 A (at 200 V ac)

For 460-W power supply:
5.5 A (at 100 V ac)

2.6 A (at 200 V ac)"

Rated input frequency 50 to 60 Hz

Rated input power "For 1200-W power supply:
930 W (at 100 V ac)

1348 W (at 200 V ac)

For 750-W power supply:
857 W (at 100 V ac)

824 W (at 200 V ac)

For 460-W power supply:
526 W (at 100 V ac)

505 W (at 200 V ac)"

BTU Rating maximum "For 1200-W power supply:
3530 BTU/hr (at 100 V ac)

4600 BTU/hr (at 200 V ac)

For 750-W power supply:
2925 BTU/hr (at 100 V ac)

2812 BTU/hr (at 200 V ac)

For 460-W power supply:
1794 BTU/hr (at 100 V ac)

1725 BTU/hr (at 200 V ac)"

Power Supply Output (per power supply)

Rated Steady-State power "For 1200-W power supply:
800 W (at 100 V ac)

900 W (at 120 V ac)

1200 W (at 200 to 240 V ac)

For 750-W power supply:
750 W (at 100 to 120 V ac)

750 W (at 200 to 240 V ac)

For 460-W power supply:
460 W (at 100 to 120 V ac)

460 W (at 200 to 240 V ac)"

Maximum peak power "For 1200-W power supply:
800 W (at 100 V ac)

900 W (at 120 V ac)

1200 W (at 200 to 240 V ac)

For 750-W power supply:
750 W (at 100 to 120 V ac)

750 W (at 200 to 240 V ac)

For 460-W power supply:
460 W (at 100 to 120 V ac)

460 W (at 200 to 240 V ac)"

top

Environmental specifications

Specification Description

Operating temperature 10° to 35°C (50° to 95°F) at sea level with an altitude derating of 1.0°C per every 304.8 m (1.8°F per every 1000 ft) above sea level to a maximum of 3048 m (10,000 ft), no direct sustained sunlight. Maximum rate of change is 10°C/hr (18°F/hr). The upper limit may be limited by the type and number of options installed. System performance may be reduced if operating with a fan fault or above 30°C (86°F).

Non-operating temperature -30° to 60°C (-22° to 140°F). Maximum rate of change is 20°C/hr (36°F/hr).

Shipping temperature -30° to 50°C (-22° to 122°F)

Storage temperature -30° to 60°C (-22° to 140°F)

Maximum wet bulb temperature 28°C (82.4°F)

Operating relative humidity 10% to 90% relative humidity (Rh), 28°C (82.4°F) maximum wet bulb temperature, non-condensing.

Non-operating relative humidity 5% to 95% relative humidity (Rh), 38.7°C (101.7°F) maximum wet bulb temperature, non-condensing.

Operating altitude 3048 m (10,000 ft). This value may be limited by the type and number of options installed. Maximum allowable altitude change rate is 457 m/min (1500 ft/min).

Non-operating altitude 9144 m (30,000 ft). Maximum allowable altitude change rate is 457 m/min (1500 ft/min).

Acoustic noise1 "Listed are the declared A-Weighted sound power levels (LWAd) and declared average bystander position A-Weighted sound pressure levels (LpAm) when the product is operating in a 23°C ambient environment. Noise emissions were measured in accordance with ISO 7779 (ECMA 74) and declared in accordance with ISO 9296 (ECMA 109). The listed sound levels apply to standard shipping configurations. Additional options may result in increased sound levels.
 Entry
Base
Performance
Idle
LWAd
4.1 B
4.1 B
4.1 B
LpAm
25 dBA
25 dBA
25 dBA
Operating
LWAd
4.3 B
4.7 B
5.0 B
LpAm
27 dBA
31 dBA
35 dBA"

NOTE:The Listed sound levels apply to standard shipping configurations. Additional options may result in increased sound levels.

top

Safety certifications

Specification Description

Emissions Classification (EMC)

FCC Rating Class A

Normative standards1,2 CISPR 22; EN55022; EN55024; FCC CFR 47, Pt 15; ICES-003; CNS13438; GB9254; K22;K24; EN 61000-3-2; EN 61000-3-3; EN 60950-1; IEC 60950-1

"NOTE:Product conformance to cited product specifications is based on sample (type) testing, evaluation, or assessment. This product or family of products is eligible to bear the appropriate compliance logos and statements.

The Listed sound levels apply to standard shipping configurations. Additional options may result in increased sound levels."